Cressi Archimede Manuel d'utilisateur Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 42
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
167
IIt is recommended that before diving at altitude, wait at least
three hours after arriving at your diving destination. This will
allow a partial release of the residual nitrogen from the body.
The atmospheric pressure at higher altitudes is lower than at
sea level. Therefore, the diver has additional nitrogen in his
body than at the lower altitudes. The excess is gradually
released and the balance re-established within a couple of
days. At this point it is important to check:
The low battery indicator. It should not be on or flashing (pic-
ture 2 a-b).
The computer display is operating. All liquid crystal segments
should be displaying.
WARNING: Should the display show the symbol of a low
battery (picture 2 a-b), the computer must NOT be used.
Additionally, should it display during a dive, the diver must
immediately surface. A battery replacement is required as
outlined in chapter 5.
2.3. - PARAMETERS SETTING.
In order to set the dive’s parameters, you must depress the
central button B (Mode), and the icon relating to the
program
you want to use will be shown (picture.3): , for air dives
( ) or Nitrox, mixture(s), or if you want to use
the depth meter /timer program.
NOTE: Archimedes II computer is preset on pro-
gram.
2.3.1. - DIVE program parameters setting.
NOTE: Archimedes II computer is preset on pro-
gram.
This is the basic program with which the Archimedes II is set.
It is possible to modify its parameters by repeatedly depres-
sing button A ( ), which allows you to select, in the following
order, the dive’s parameters relating to:
PO2 Mix 1 -> FO2 Mix 1 -> PO2 Mix 2 -> FO2 Mix 2
-> Safety Factor -> Max Depth -> OFF/ON -> DIVE
that is:
• PO2 Mix 1 is the partial pressure of the former of the two
Nitrox mixtures, so that Archimedes II can make its decom-
pression computations. The diver can set it on values
between 1.0 bar (included) and 1.6 bar (included), by varia-
tions of 0.1 bar, obtained at each pressure of button C ( );
NOTE: By varying of max PO2 setting (picture 3), the com-
puter also indicates the maximum depth (MAX) that may be
reached with that mixture.
WARNING: Both mixtures’ PO2 factory set on a basic value
(default) of 1.4 bar, both for air dives and for Nitrox mixture
dives. The diver is then following the most conservative
values recommended for sport dives. Different PO2 values
may be set as shown in chapter 3.3. The set value will be
memorized in the computer until the diver chooses another
setting.
i
ENGLISH
Manuale ARCHIMEDE II 2008:Manuale 6 26-06-2008 8:26 Pagina 167
Vue de la page 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 41 42

Commentaires sur ces manuels

Pas de commentaire